CAROLINA BIOLOGICAL SUPPLY CO -- 86-9051, IODINE POTASSIUM IODIDE -- -
=====================  Product Identification  =====================

Product ID:86-9051, IODINE POTASSIUM IODIDE
MSDS Date:09/05/2000
FSC:NIIN:Submitter:D DG
Status Code:A
MSDS Number: CLDBM
=== Responsible Party ===
Company Name:CAROLINA BIOLOGICAL SUPPLY CO
Address:2700 YORK RD
City:BURLINGTON
State:NC
ZIP:27215-3387
Country:US
Info Phone Num:800-227-1150
Emergency Phone Num:800-227-1150/910-584-0381(OUT SIDE)
Chemtrec Ind/Phone:(800)424-9300
CAGE:59896
=== Contractor Identification ===
Company Name:CAROLINA BIOLOGICAL SUPPLY CO
Address:2700 YORK RD
Box:City:BURLINGTON
State:NC
ZIP:27215-3387
Country:US
Phone:800-227-1150/910-584-0381
Contract Num:MDA414-01-P-1321
CAGE:59896

=============  Composition/Information on Ingredients  =============

Ingred Name:IODINE
CAS:7553-56-2
RTECS #:NN1575000
= Wt:1.
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C 0.1 PPM
ACGIH TLV:C 0.1 PPM; 9596

Ingred Name:POTASSIUM IODIDE
CAS:7681-11-0
RTECS #:TT2975000
= Wt:2.
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT): 14 G/KG (IODINE)
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MAY BE HARMFUL IF SWALLOWED, INHALED
    OR ABSORED THROUGH THE SKIN. EYE CONTACT MAY CAUSE IRRITATION. SKIN
    CONTACT MAY CAUSE IRRITATION. INGESTION MAY CAUSE GASTROINTESTINAL
    DISCOMFORT. INHALATION MAY C AUSE IRRITATION TO RESPIRATORY TRACT.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
    CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
    CARCINOGENS.
Effects of Overexposure:EYE IRRITATION, SKIN IRRITATION,
    GASTROINTESTINAL DISCOMFORT, RESPIRATORY TRACT IRRITATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING EYELIDS
    OPEN. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
    WASH WITH SOAP AND WATER. IF IRRITATION PERSIST, GET MEDICAL
    ATTENTION. INH ALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. GET
    MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. DRINK WATER.
    GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, ALCOHOL FOAM
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR FULL PROTECTIVE
    EQUIPMENT AND NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA OF SPILL. ELIMINATE ALL SOURCES
    OF IGNITION. REMOVE ALL NON-ESSENTIAL PERSONNEL FORM AREA. WEAR
    PROPER PROTECTIVE EQUIPMENT AND CLOTHING. ABSORB MATERAIL WITH
    SUITABLE ABSORBANT AND CON TAINERIZE FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A TIGHTLY CLOSED CONTAINER IN
    A COOL, DRY, WELL VENTILATED AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:A NIOSH/MSHA CHEMICAL CARTRIDGE RESPIRATOR
    SHOULD BE WORN IF PEL OR TLV IS EXCEEDED.
Ventilation:LOCAL EXHAUST AND MECHANICAL (GENERAL) VENTILATION AS
    REQUIRED TO MAINTAIN EXPOSURE LEVELS.
Protective Gloves:RUBBER, NEOPRENE, PVC OR EQUIVALENT
Eye Protection:SPLASH PROOF CHEMICAL SAFETY GOGGLES
Other Protective Equipment:CHEMICAL RESISTANT CLOTHING AS NECESSARY TO
    PREVENT SKIN CONTACT. AN EMERGENCY EYEWASH AND SHOWER SHOULD BE
    AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
    BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

HCC:N1
Solubility in Water:MISCIBLE
Appearance and Odor:DARK BROWN LIQUID WITH SLIGHT CHARACTERISTIC ODOR
    OF IODINE
Percent Volatiles by Volume:98 %

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

===================  Toxicological Information	===================

Toxicological Information:TOXICITY DATA: POTASSIUM IODIDE: IPR-MUS
    LD50: 1117 MG/KG. ORL-RAT LD50: 1862 MG/KG. IODINE: IHL-RAT LCL0:
    800 MG/M3. ORL-RAT LD50: 14 G/KG.

=====================  Ecological Information  =====================

Ecological:EPA WASTE NUMBERS: IODINE D002.

====================  Disposal Considerations  ====================

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
    ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSAL CONTAINER OR
    LINER IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

===================  MSDS Transport Information  ===================

Transport Information:CORROSIVE LIQUIDS, N.O.S. (IODINE), 8, UN1760,
    III.  30 ML BOTTLE IS A SMALL QUANTITY EXCEPTION.

=====================  Regulatory Information  =====================

SARA Title III Information:HAZARD CATEGORY FOR SARA SECTION 311/312
    REPORTING: ACUTE. SARA TITLE III: POTASSIUM IODIDE: SARA EHS
    SECTION 302 TPQ: NO,  SARA SECTION 313 CHEMICALS/NAME LIST: NO,
    SARA SECTION 313 CHEMICALS/CHEMICA L LIST: NO, CERCLA SECTION 103
    RQ (LBS): NO, RCRA SECTION 261.33: NO;  IODINE: SARA EHS SECTION
    302 TPQ: NO,  SARA SECTION 313 CHEMICALS/NAME LIST: NO, SARA
    SECTION 313 CHEMICALS/CHEMICAL LIST: NO, CE RCLA SECTION 103 RQ
    (LBS): NO, RCRA SECTION 261.33: NO
Federal Regulatory Information:EPA TSCA STATUS: ON TSCA INVENTORY.
State Regulatory Information:NO DATA PROVIDED BY MANUFACTURER.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.